(Software Version 3.2)Envizio Pro™ & Envizio Pro II™Installation & Operation Manual
Calibration Reference Sheetviii Envizio Pro and Envizio Pro II Installation and Operation ManualUnit Definitions and ConversionsUnit of Measure Defini
Chapter 790 Envizio Pro and Envizio Pro II Installation and Operation ManualThe Quick Access Bar appears along the top of the Main Tools menu screen.T
7Manual No. 016-0171-148 91Tools MenuVehicle MenuAccess the Vehicle menu to setup or modify vehicle profiles for each machine or implement with which
Chapter 792 Envizio Pro and Envizio Pro II Installation and Operation ManualOn-Screen KeyboardData entry on the Envizio Pro and Envizio Pro II is quic
7Manual No. 016-0171-148 93Tools MenuSystem MenuThe System menu contains the options for setting up how the Envizio Pro or Envizio Pro II will interfa
Chapter 794 Envizio Pro and Envizio Pro II Installation and Operation ManualProduct Control OptionsThe following settings will configure the field com
7Manual No. 016-0171-148 95Tools MenuCAN Sprayer/Spreader ControlSelect ‘CAN Sprayer/Spreader Control’ if the Envizio Pro or Envizio Pro II will be us
Chapter 796 Envizio Pro and Envizio Pro II Installation and Operation ManualBoom Master OptionsThe boom master options allow the operator to setup the
7Manual No. 016-0171-148 97Tools MenuSerial Port ConfigurationThe Envizio Pro and Envizio Pro II can control an optional external lightbar connected t
Chapter 798 Envizio Pro and Envizio Pro II Installation and Operation ManualCAN DiagnosticsThe CAN Diagnostics screen displays the software version, s
7Manual No. 016-0171-148 99Tools MenuThe Product Control Configuration screen contains several of the calibration numbers which the field computer req
CHAPTER1Manual No. 016-0171-148 1C hapter 1Important Safety InformationSafety InformationRead this manual and the operation and safety instructions in
Chapter 7100 Envizio Pro and Envizio Pro II Installation and Operation ManualSpeed CalThe current speed cal is displayed on the Speed Cal button. Touc
7Manual No. 016-0171-148 101Tools MenuValveTouch the Valve button to access the Valve Calibration screen.Valve TypeSelect the type of control valve us
Chapter 7102 Envizio Pro and Envizio Pro II Installation and Operation ManualValve Advance (Standard, Fast or Fast Close Valve)This feature allows the
7Manual No. 016-0171-148 103Tools MenuCalibration Assistant. The calibration assistant allows the operator to increase or decrease the PWM output usin
Chapter 7104 Envizio Pro and Envizio Pro II Installation and Operation ManualPWM Calibration ScreenIn the manual calibration and calibration assistant
7Manual No. 016-0171-148 105Tools MenuMin PWM. Enter a Min PWM value to set the minimum desired RPM or hydraulic output (zero point or shutoff point)
Chapter 7106 Envizio Pro and Envizio Pro II Installation and Operation ManualRate CalEnter the target rate for the product controlled by the selected
7Manual No. 016-0171-148 107Tools MenuTiered Boom SettingsA tiered boom configuration has two or more booms stacked one directly in front of the other
Chapter 7108 Envizio Pro and Envizio Pro II Installation and Operation ManualPrescription (Rx) SettingsIf an optional variable rate application (VRA)
7Manual No. 016-0171-148 109Tools MenuVolume and Area SettingsThe volume/area Settings screen allows the operator to program the tank or bin volume fo
Chapter 12 Envizio Pro and Envizio Pro II Installation and Operation ManualHydraulic Safety• Raven Industries recommends that appropriate protective e
Chapter 7110 Envizio Pro and Envizio Pro II Installation and Operation ManualFeature SettingsTouch the Feature Settings icon to configure additional f
7Manual No. 016-0171-148 111Tools MenuThe ratio rate calibration value is entered as the ratio of injected chemical to carrier in ounces per gallon [d
Chapter 7112 Envizio Pro and Envizio Pro II Installation and Operation ManualAlarm SettingsThe Alarm Settings screen is used to set the values at whic
7Manual No. 016-0171-148 113Tools Menualarm or 0 to display an error any time the flow switch and pump encoder do not match. The default value for the
Chapter 7114 Envizio Pro and Envizio Pro II Installation and Operation ManualSection AssignmentsThe Section Assignment screen allows the operator to a
7Manual No. 016-0171-148 115Tools MenuSteeringIf an optional automated steering system has been installed, the Steering icon will be displayed in the
Chapter 7116 Envizio Pro and Envizio Pro II Installation and Operation ManualThe direction of travel icon (shown to the right) will be displayed on th
7Manual No. 016-0171-148 117Tools MenuMode. •Displays the current differential fix status. The mode value will display:• ‘0’ or ‘1’ if no differential
Chapter 7118 Envizio Pro and Envizio Pro II Installation and Operation ManualDirection of Travel IndicatorThis indicator displays the last direction o
7Manual No. 016-0171-148 119Tools MenuDifferentialSelect the Differential icon from the GPS menu to set up the internal receiver for the desired GPS c
CHAPTER2Manual No. 016-0171-148 3C hapter 2IntroductionCongratulations on the purchase of the Raven Envizio Pro or Envizio Pro II precision applicatio
Chapter 7120 Envizio Pro and Envizio Pro II Installation and Operation ManualThe PRN scroll list allows the operator to manually set the PRN, or pseud
7Manual No. 016-0171-148 121Tools Menuwell as the baud rate for those messages. Contact a local Slingshot dealer for more information on the Slingshot
Chapter 7122 Envizio Pro and Envizio Pro II Installation and Operation ManualSimulated Radar OutputTouch the ‘Next’ icon displayed on the GPS Output s
7Manual No. 016-0171-148 123Tools MenuInternal GPS ReceiverTo use the internal receiver, select the ‘Internal GPS Receiver’ option. Verify settings on
Chapter 7124 Envizio Pro and Envizio Pro II Installation and Operation ManualComputer MenuThe Computer menu contains settings and preferences for the
7Manual No. 016-0171-148 125Tools MenuDisplay ModeSelect Day or Night to adjust the guidance screen for day or night operations.Screen BrightnessThe S
Chapter 7126 Envizio Pro and Envizio Pro II Installation and Operation ManualRegionSelect the Region icon to modify display settings for the region in
7Manual No. 016-0171-148 127Tools MenuUpdatesAccess the Updates screen to update the field computer software or to register a special feature, such as
Chapter 7128 Envizio Pro and Envizio Pro II Installation and Operation ManualThe Raven dealer will require the Machine ID and Validation Code informat
7Manual No. 016-0171-148 129Tools MenuVehicle MenuUse the Vehicle menu to configure the field computer for the machine or implement configuration. The
Chapter 24 Envizio Pro and Envizio Pro II Installation and Operation ManualEnvizio Pro and Envizio Pro II FeaturesThe following descriptions offer a b
Chapter 7130 Envizio Pro and Envizio Pro II Installation and Operation ManualOffsetsTo properly display the vehicle location within a field and create
7Manual No. 016-0171-148 131Tools MenuFore/AftThe fore/aft offset is the distance of the boom or implement in front or behind the GPS antenna. The for
Chapter 7132 Envizio Pro and Envizio Pro II Installation and Operation ManualTo set the left/right value:1. Touch the current left/right value display
7Manual No. 016-0171-148 133Tools MenuSection Setup1. On the Section Configuration screen, touch the Next icon to begin configuring sections.The Numbe
Chapter 7134 Envizio Pro and Envizio Pro II Installation and Operation Manual3. Configure the width of each section starting with the far left section
7Manual No. 016-0171-148 135Tools MenuConfiguring Section LabelsTo customize the section labels displayed on the field computer, touch the ‘Configure
Chapter 7136 Envizio Pro and Envizio Pro II Installation and Operation ManualManually Configure SectionsIf the boom or implement is not aligned end-to
7Manual No. 016-0171-148 137Tools MenuShow AllThe Show All icon along the top of the screen displays the Tools Menu overview screen. Touch this icon t
Chapter 7138 Envizio Pro and Envizio Pro II Installation and Operation Manual
CHAPTER8Manual No. 016-0171-148 139C hapter 8Software Updates and File MaintenanceOverviewThe Envizio Pro and Envizio Pro II File Maintenance feature
Manual No. 016-0171-148 5Introduction2Internal DGPS ReceiverBoth the Envizio Pro and Envizio Pro II offer an internal Differential GPS (DGPS) receiver
Chapter 8140 Envizio Pro and Envizio Pro II Installation and Operation ManualFile MaintenanceCoverage maps and field boundaries, saved A-B Lines, as w
8Manual No. 016-0171-148 141Software Updates and File MaintenancePerforming File Maintenance1. Open the Tools menu and select the File Maintenance ico
Chapter 8142 Envizio Pro and Envizio Pro II Installation and Operation Manual4. To begin working with the selected file type, touch the transfer to or
8Manual No. 016-0171-148 143Software Updates and File MaintenanceTransfer To Field ComputerSelect the left icon to transfer a selected file to the fie
Chapter 8144 Envizio Pro and Envizio Pro II Installation and Operation ManualWork OrdersJob information for each job transferred to the USB flash driv
8Manual No. 016-0171-148 145Software Updates and File MaintenanceUpdatesSoftware updates for the field computer will be available periodically from th
Chapter 8146 Envizio Pro and Envizio Pro II Installation and Operation Manual5. Once the download has finished, unzip or extract the software update t
8Manual No. 016-0171-148 147Software Updates and File Maintenance3. Insert the USB flash drive with the extracted software update into and available U
Chapter 8148 Envizio Pro and Envizio Pro II Installation and Operation Manual
CHAPTER9Manual No. 016-0171-148 149C hapter 9Using AccuBoom™IntroductionAccuBoom is an automatic boom or implement section control feature that can be
Chapter 26 Envizio Pro and Envizio Pro II Installation and Operation ManualOptional FeaturesFlexibility of the Raven Envizio Pro and Envizio Pro II me
Chapter 9150 Envizio Pro and Envizio Pro II Installation and Operation ManualAccuBoom™ SetupPrior to using the AccuBoom feature of the field computer,
9Manual No. 016-0171-148 151Using AccuBoom™To enable the AccuBoom Override:1. Touch this icon to display the AccuBoom Popup.2. Touch the Override butt
Chapter 9152 Envizio Pro and Envizio Pro II Installation and Operation Manualmaneuvering when crossing spray zones. Higher aggressiveness settings wil
9Manual No. 016-0171-148 153Using AccuBoom™Off PressureSet the pressure at which the field computer will shut off all AccuBoom controlled sections and
Chapter 9154 Envizio Pro and Envizio Pro II Installation and Operation ManualEnabling AccuBoom™To use the AccuBoom feature with the product control sy
9Manual No. 016-0171-148 155Using AccuBoom™3. Select the Enable AccuBoom option to allow the AccuBoom feature to automatically control boom or impleme
Chapter 9156 Envizio Pro and Envizio Pro II Installation and Operation ManualAccuBoom™ ModesThe available modes for operating AccuBoom are:• Standard
9Manual No. 016-0171-148 157Using AccuBoom™Using Spray Zone MapsAn AccuBoom spray zone map may contain numerous spray and no-spray zones for each fiel
Chapter 9158 Envizio Pro and Envizio Pro II Installation and Operation ManualAccuBoom™ Mapping ToolsThe following tools are available via the Menu on
9Manual No. 016-0171-148 159Using AccuBoom™StopWhen finished recording a Zone or Boundary, touch the Stop button to close Zone or Boundary.Note: The f
Manual No. 016-0171-148 7Introduction2Resistive Touch Screen TechnologyResistive touch screen technology offers clear visibility across a range of lig
Chapter 9160 Envizio Pro and Envizio Pro II Installation and Operation Manual2. Select the Record Field Boundary button to begin recording a new AccuB
9Manual No. 016-0171-148 161Using AccuBoom™5. The Guidance screen will re-appear and the field computer will begin recording the feature at the select
Chapter 9162 Envizio Pro and Envizio Pro II Installation and Operation ManualAccuBoom™ Spray Zone Map ExamplesThe following screens are examples of Ac
Manual No. 016-0171-148 163Using AccuBoom™FIGURE 3. Guidance screen in Down Field View with Completed Field BoundaryFIGURE 4. Field Review Mode with C
Chapter 9164 Envizio Pro and Envizio Pro II Installation and Operation Manual
CHAPTER10Manual No. 016-0171-148 165C hapter 10Using AutoBoom™IntroductionThe AutoBoom feature, used in conjunction with an Envizio Pro or Envizio Pro
Chapter 10166 Envizio Pro and Envizio Pro II Installation and Operation ManualUltraGlideUltraGlide AutoBoom replaces the gauge wheels with state-of-th
10Manual No. 016-0171-148 167Using AutoBoom™AutoBoom™ IndicatorsThe following sections offer examples of the AutoBoom status indicators which may be d
Chapter 10168 Envizio Pro and Envizio Pro II Installation and Operation Manual
CHAPTER11Manual No. 016-0171-148 169C hapter 11TroubleshootingTroubleshooting InformationThis chapter contains information on troubleshooting possible
Chapter 28 Envizio Pro and Envizio Pro II Installation and Operation ManualRear PanelThe following is a brief overview of the connections and ports av
Chapter 11170 Envizio Pro and Envizio Pro II Installation and Operation ManualSetup IssuesJob IssuesRed DGPS Status indicator on the Home screen• GPS
Manual No. 016-0171-148 171Troubleshooting11Coverage Map IssuesError MessagesThis section contains information regarding possible error messages displ
Chapter 11172 Envizio Pro and Envizio Pro II Installation and Operation ManualGPS Error MessagesIssue Possible Cause SolutionGuidance Not Available• D
Manual No. 016-0171-148 173Troubleshooting11CAN TroubleshootingAlthough the control algorithm is located within the CAN node, all of the same troubles
Chapter 11174 Envizio Pro and Envizio Pro II Installation and Operation Manual
APPENDIXAManual No. 016-0171-148 175A ppend ix ACalculating the Calibration ValuesSpeed CalRaven industries recommends the following values for the in
Appendix A176 Envizio Pro and Envizio Pro II Installation and Operation ManualFor Example:Assume that the field computer odometer reads 5000 [980] aft
Manual No. 016-0171-148 177Calculating the Calibration ValuesAdjusting for Additional MagnetsTypically, four magnets are used with the wheel drive spe
Appendix A178 Envizio Pro and Envizio Pro II Installation and Operation Manual5. Touch the Speed button and use the keypad to enter the Corrected Spee
Manual No. 016-0171-148 179Calculating the Calibration ValuesMeter CalThe flow meter calibration number can be found on the tag attached to each flow
Manual No. 016-0171-148 9IntroductionCare and UseRefer to the following guidelines for proper care and use of the Envizio Pro and Envizio Pro II field
Appendix A180 Envizio Pro and Envizio Pro II Installation and Operation ManualDead Band DigitThe Dead Band digit is the allowable difference between t
Manual No. 016-0171-148 181Calculating the Calibration ValuesTiered Boom SettingsA tiered boom configuration has two or more booms stacked one directl
Appendix A182 Envizio Pro and Envizio Pro II Installation and Operation ManualThus, as the volume per minute increases, the following tier switching s
Manual No. 016-0171-148 183Calculating the Calibration ValuesGranular ApplicationsBoom CalFor Gran 1 (single belt) applications, enter the total width
Appendix A184 Envizio Pro and Envizio Pro II Installation and Operation ManualVerification of Spreader ConstantTo verify and refine the spreader const
Manual No. 016-0171-148 185Calculating the Calibration ValuesSpinner RPMFor spinner box machines, use a product control node capable of controlling sp
Appendix A186 Envizio Pro and Envizio Pro II Installation and Operation ManualAdditional Calibration DataAlthough not required operation, the followin
APPENDIXBManual No. 016-0171-148 187A ppend ix BTesting CablesSpeed Sensor Extension CableDisconnect the extension cable from the speed sensor assembl
Appendix B188 Envizio Pro and Envizio Pro II Installation and Operation ManualFlow Meter/Encoder Extension CableBefore starting this test, disconnect
APPENDIXCManual No. 016-0171-148 189A ppend ix CBogballe Calibrator Zurf InterfaceInterface the Envizio Pro or Envizio Pro II with the Bogballe Calibr
While every effort has been made to ensure the accuracy of this document, Raven Industries assumes no responsibility for omissions and err
Chapter 210 Envizio Pro and Envizio Pro II Installation and Operation ManualAmp Connector Pin DefinitionsMain Amp Connector Auxiliary Amp Connector1.B
Appendix C190 Envizio Pro and Envizio Pro II Installation and Operation ManualBogballe Setup and ConfigurationNote: When the Envizio Pro or Envizio Pr
Manual No. 016-0171-148 191Bogballe Calibrator Zurf InterfaceFIGURE 2. Bogballe Offset Distance Calculation4. From the field computer Home screen, tou
Appendix C192 Envizio Pro and Envizio Pro II Installation and Operation ManualAccuBoom™ ConfigurationUse the following procedure to calibrate the Accu
Manual No. 016-0171-148 193Bogballe Calibrator Zurf InterfaceOperationWhen interfacing with the Bogballe Calibrator Zurf console, the field computer d
Appendix C194 Envizio Pro and Envizio Pro II Installation and Operation ManualApplication ReportsWhile interfacing with a Bogballe Calibrator Zurf con
APPENDIXDManual No. 016-0171-148 195A ppend ix DWireless Communications & Remote ServiceThe Envizio Pro or Envizio Pro II, with a Slingshot Field
Appendix D196 Envizio Pro and Envizio Pro II Installation and Operation ManualThe following icons may be displayed in the wireless status area:The wir
Manual No. 016-0171-148 197Wireless Communications & Remote ServiceRemote ServiceThe Remote Service feature allows a service technician to view an
Appendix D198 Envizio Pro and Envizio Pro II Installation and Operation ManualFile ManagerAccess the Wireless File Manager to view a history of files
Manual No. 016-0171-148 199Wireless Communications & Remote ServiceTo register:1. Touch the Wireless Status icon on the Home screen and select the
CHAPTER3Manual No. 016-0171-148 11C hapter 3InstallationOverview of the Installation ProcessThe following is intended as an overview of the installati
Appendix D200 Envizio Pro and Envizio Pro II Installation and Operation Manual
APPENDIXEManual No. 016-0171-148 201A ppend ix EUpdating CAN Nodes via the Envizio Pro or Envizio Pro IIEnvizio Pro and Envizio Pro II with version 2.
Appendix E202 Envizio Pro and Envizio Pro II Installation and Operation Manual4. On the CAN Diagnostics screen, select the to begin the CAN Update P
APPENDIXFManual No. 016-0171-148 203A ppend ix FReference of IconsNavigationThe following icons will be used to navigate within the menu screens and t
Appendix F204 Envizio Pro and Envizio Pro II Installation and Operation ManualThe Cycle Product icons are used when more than one product is connected
Manual No. 016-0171-148 205Reference of IconsGPS StatusThe current source and status of DGPS signal is displayed in the upper, left corner of the Home
Appendix F206 Envizio Pro and Envizio Pro II Installation and Operation ManualWireless Communications StatusThe current status of wireless communicati
Manual No. 016-0171-148 207Reference of IconsFile MaintenanceTo begin file maintenance from the Home screen:1. Touch Tools Menu icon.2. Select the Fil
Appendix F208 Envizio Pro and Envizio Pro II Installation and Operation ManualCAN DiagnosticsTouch this icon to readdress product control nodes connec
Manual No. 016-0171-148 209Reference of IconsGuidance PatternsThe following icons represent the available Guidance patterns available for use with the
Chapter 312 Envizio Pro and Envizio Pro II Installation and Operation ManualKit ContentsBefore proceeding with installation of the Envizio Pro or Envi
Appendix F210 Envizio Pro and Envizio Pro II Installation and Operation ManualGuidance ViewsThe following views may be selected for viewing the Guidan
Manual No. 016-0171-148 211Reference of IconsToggle Maps on the Guidance ScreenDuring a job with an active prescription or spray zone map, the field c
Appendix F212 Envizio Pro and Envizio Pro II Installation and Operation ManualSet B by HeadingThe Set B by Heading feature is only available with the
Manual No. 016-0171-148 213Reference of IconsOn-Screen Nudge EnabledThe following icons will be displayed on the Guidance screen if the on-screen nudg
Appendix F214 Envizio Pro and Envizio Pro II Installation and Operation ManualPause, Resume and End BoundariesThe following icons will appear on the G
Manual No. 016-0171-148 215Reference of IconsAccuBoom™The following tools and icons will be displayed when working in a job with the AccuBoom feature
Appendix F216 Envizio Pro and Envizio Pro II Installation and Operation ManualStopWhen finished recording a Zone or Boundary, touch the Stop button to
IndexManual No. 016-0171-148 217AA-B Path Tools 76AccuBoom™ 149Creating a Spray Zone Map 159Enable Override Popup 153Enabling 154Examples of Spray Zon
Index218 Envizio Pro & Envizio Pro II Installation & Operation ManualSource 122GPS Status 54Guidance PatternsEnhanced Last Pass 60Fixed Contou
IndexManual No. 016-0171-148 219Rx SettingsSee Prescription (Rx) SettingsSScreensGuidance Screen 64Home Screen 53Section Assignments 114Serial Port Co
3Manual No. 016-0171-148 13InstallationFIGURE 1. Envizio Pro II Kit ContentsOther Available Components Part NumberCAN Switch Box to Envizio Pro Kit 11
Index220 Envizio Pro & Envizio Pro II Installation & Operation Manual
Raven Industries will not assume any expense or liability for repairs made outside our facilities without written consent. Raven Industries is not r
Notice: This document and the information provided are the property of Raven Industries, Inc. and may only be used as authorized by Raven Industries,
Chapter 314 Envizio Pro and Envizio Pro II Installation and Operation ManualEnvizio ProTABLE 2. Envizio Pro Kit ContentsEnvizio Pro KitsEnvizio Pro wi
3Manual No. 016-0171-148 15InstallationFIGURE 2. Envizio Pro Kit ContentsOther Available Components Part NumberAuxiliary Interface Cable 115-0171-745H
Chapter 316 Envizio Pro and Envizio Pro II Installation and Operation ManualMounting the Field ComputerRefer to the following requirements when select
3Manual No. 016-0171-148 17InstallationCable Platforms and ConnectionsTwo cable platform options are available for use with the Envizio Pro or Envizio
Chapter 318 Envizio Pro and Envizio Pro II Installation and Operation Manual1. Route the conduit with red and white leads to a clean, controlled power
3Manual No. 016-0171-148 19InstallationGeneration 2 Cable ConnectionsThe chassis cable platform requires the following components:• Machine specific c
Table of ContentsManual No. 016-0171-148 iCalibration Reference Sheet ...
Chapter 320 Envizio Pro and Envizio Pro II Installation and Operation ManualChassis Interface Cable and CAN Switch Box ConnectionNote: The CAN Switch
3Manual No. 016-0171-148 21InstallationConnecting the Antenna to the Internal DGPS Receiver1. (Helix antennas only) Connect the antenna cable (P/N 115
Chapter 322 Envizio Pro and Envizio Pro II Installation and Operation ManualInstalling Optional EquipmentThe following sections offer descriptions of
3Manual No. 016-0171-148 23InstallationAccuBoom™Refer to the machine specific installation materials for instructions on installing AccuBoom on the ma
Chapter 324 Envizio Pro and Envizio Pro II Installation and Operation ManualIf connected directly to the ‘DGPS’ connector on the main interface cable
Manual No. 016-0171-148 25InstallationThe Envizio Pro or Envizio Pro II may be connected to a Raven serial control console via a serial port connectio
Chapter 326 Envizio Pro and Envizio Pro II Installation and Operation Manual
CHAPTER4Manual No. 016-0171-148 27C hapter 4CAN Networking and DiagnosticsA Controller Area Network, or CAN, system is a high-integrity serial data co
Chapter 428 Envizio Pro and Envizio Pro II Installation and Operation ManualFIGURE 1. Envizio Pro Single Product CAN Control System
4Manual No. 016-0171-148 29CAN Networking and DiagnosticsFIGURE 2. Envizio Pro Dual Product (Liquid/Granular) CAN Control System
Table of Contentsii Envizio Pro & Envizio Pro II Installation & Operation ManualChapter 4 CAN Networking and Diagnostics ...
Chapter 430 Envizio Pro and Envizio Pro II Installation and Operation ManualCAN DiagnosticsThe field computer must be able to communicate with the CAN
4Manual No. 016-0171-148 31CAN Networking and DiagnosticsNode Version InformationThe CAN Diagnostics screen displays the software version, software re
Chapter 432 Envizio Pro and Envizio Pro II Installation and Operation ManualReset CANbus DefaultsTo reset all product control nodes on the system:1. F
4Manual No. 016-0171-148 33CAN Networking and DiagnosticsHardware SummarySelect a node from the list displayed on the CAN Diagnostics screen and touch
Chapter 434 Envizio Pro and Envizio Pro II Installation and Operation ManualCAN TroubleshootingAlthough the control algorithm is located within the CA
CHAPTER5Manual No. 016-0171-148 35C hapter 5Startup, Initial Setup and Setup WizardsOverviewThe first time the Envizio Pro or Envizio Pro II field com
Chapter 536 Envizio Pro and Envizio Pro II Installation and Operation ManualLaunching WizardsTo start the setup wizards after the initial power up has
5Manual No. 016-0171-148 37Startup, Initial Setup and Setup WizardsTouch Screen CalibrationThe touch screen displays an arrow in the location last sel
Chapter 538 Envizio Pro and Envizio Pro II Installation and Operation ManualInitial Setup WizardThe initial setup wizard will automatically begin when
5Manual No. 016-0171-148 39Startup, Initial Setup and Setup WizardsOffsetsThe antenna offset is used to calibrate the field computer for the relative
Table of ContentsManual No. 016-0171-148 iiiGuidance Screen ...
Chapter 540 Envizio Pro and Envizio Pro II Installation and Operation ManualLeft or Right OffsetThe left/right offset is the distance from the GPS ant
5Manual No. 016-0171-148 41Startup, Initial Setup and Setup WizardsControl InterfaceThe multi-functional capabilities of the Envizio Pro and Envizio P
Chapter 542 Envizio Pro and Envizio Pro II Installation and Operation Manual•CAN Sprayer/Spreader Control - Select ‘CAN Sprayer/Spreader Control’ if t
5Manual No. 016-0171-148 43Startup, Initial Setup and Setup WizardsNone/Raven Serial ConsoleThe following options are available if the product control
Chapter 544 Envizio Pro and Envizio Pro II Installation and Operation ManualSerial Port ConfigurationTouch the Serial Port icon in the upper right cor
5Manual No. 016-0171-148 45Startup, Initial Setup and Setup WizardsThe Setup Wizard Menu will display the available setup wizards which may be used to
Chapter 546 Envizio Pro and Envizio Pro II Installation and Operation ManualSection Setup WizardThe Section setup wizard will guide the operator throu
5Manual No. 016-0171-148 47Startup, Initial Setup and Setup Wizards5. The Manual and Auto Configure buttons on the Configure Sections screen allow the
Chapter 548 Envizio Pro and Envizio Pro II Installation and Operation ManualManually Configure SectionsIf the boom or implement is not aligned end-to-
5Manual No. 016-0171-148 49Startup, Initial Setup and Setup WizardsProduct Control Setup WizardThe product control setup wizard will require the follo
Table of Contentsiv Envizio Pro & Envizio Pro II Installation & Operation ManualSection Assignments ...
Chapter 550 Envizio Pro and Envizio Pro II Installation and Operation Manualbe refined for each specific vehicle and speed sense system. See Appendix
5Manual No. 016-0171-148 51Startup, Initial Setup and Setup WizardsRaven Industries recommends the following valve calibration values for initial syst
Chapter 552 Envizio Pro and Envizio Pro II Installation and Operation Manual13. Touch the Next icon. The Section Assignments screen will be displayed.
CHAPTER6Manual No. 016-0171-148 53C hapter 6Basic OperationOverviewThis chapter contains information regarding the basic operation of the Envizio Pro
Chapter 654 Envizio Pro and Envizio Pro II Installation and Operation ManualThe Home screen offers access to the following features of the Envizio Pro
6Manual No. 016-0171-148 55Basic OperationWireless Communications StatusThe current status of wireless communication is displayed along the top of the
Chapter 656 Envizio Pro and Envizio Pro II Installation and Operation ManualTo end jobs on the Envizio Pro or Envizio Pro II:1. Open the menu on the G
6Manual No. 016-0171-148 57Basic OperationJob FilesOverviewThe Envizio Pro and Envizio Pro II stores field and product information in job files. In ge
Chapter 658 Envizio Pro and Envizio Pro II Installation and Operation ManualSetting up a JobThis section contains detailed instructions for setting up
6Manual No. 016-0171-148 59Basic OperationDirection of TravelThe last direction of travel detected by the field computer is displayed on the Start Job
Table of ContentsManual No. 016-0171-148 vLook Ahead ...
Chapter 660 Envizio Pro and Envizio Pro II Installation and Operation ManualThe Select Job screen will be displayed.To Resume an Existing Job: Select
6Manual No. 016-0171-148 61Basic OperationThe Enhanced Last Pass is well suited to provide guidance for irregular swaths due to irregular field bounda
Chapter 662 Envizio Pro and Envizio Pro II Installation and Operation ManualAccuBoom™ SetupIf the optional AccuBoom system has been installed, touch t
6Manual No. 016-0171-148 63Basic OperationThe selected Product Setup screen will be displayed.Enable Product. Select the “Enable Product” option to en
Chapter 664 Envizio Pro and Envizio Pro II Installation and Operation ManualAutoBoom™ SetupIf an optional AutoBoom system is detected on the CANbus, t
6Manual No. 016-0171-148 65Basic Operationfrom the guidance path. See the System menu section in Chapter 7, Tools Menu, to setup the lightbar display.
Chapter 666 Envizio Pro and Envizio Pro II Installation and Operation ManualEnhanced Last PassThe Last Pass pattern uses the last, or nearest, applied
6Manual No. 016-0171-148 67Basic OperationStraight (A-B) Line The Straight Line, or parallel, guidance pattern is created by drawing a straight line t
Chapter 668 Envizio Pro and Envizio Pro II Installation and Operation ManualPivotTo begin guidance using the pivot pattern, the operator must set two
6Manual No. 016-0171-148 69Basic Operation3. The In Job Nudge Settings screen will be displayed.4. The Nudge Settings screen displays the following op
Table of Contentsvi Envizio Pro & Envizio Pro II Installation & Operation ManualAppendicesAppendix A Calculating the Calibration Values...
Chapter 670 Envizio Pro and Envizio Pro II Installation and Operation ManualProduct Control FeaturesIn addition to guidance features of the Envizio Pr
6Manual No. 016-0171-148 71Basic OperationTank or Bin IndicatorThe tank or bin level indicator displays an estimate of product remaining in the tank o
Chapter 672 Envizio Pro and Envizio Pro II Installation and Operation ManualProduct Rate DisplayThe field computer displays rate information for each
6Manual No. 016-0171-148 73Basic OperationThe following information is displayed on this screen:1. Application information2. Selected product3. Contro
Chapter 674 Envizio Pro and Envizio Pro II Installation and Operation ManualDisplay Options. Additional displays may be enabled or disabled with the o
6Manual No. 016-0171-148 75Basic OperationMenuGuidance path tools, field boundary tools and additional guidance views are available by accessing the M
Chapter 676 Envizio Pro and Envizio Pro II Installation and Operation ManualSwitch to the Bird’s Eye view to change to a view from above. This view wi
6Manual No. 016-0171-148 77Basic OperationSet B by HeadingThe Set B by Heading feature is only available with the Straight Line Guidance Pattern. This
Chapter 678 Envizio Pro and Envizio Pro II Installation and Operation ManualOn-Screen Nudge EnabledThe following icons will be displayed on the Guidan
6Manual No. 016-0171-148 79Basic OperationField Review Mode ToolsIn field review mode, the following icons appear along the bottom of the Guidance scr
Manual No. 016-0171-148 viiCalibration Reference SheetRecord the settings and calibration values used when programming the field computer and keep thi
Chapter 680 Envizio Pro and Envizio Pro II Installation and Operation ManualSelect ProductThe field review mode displays coverage information based up
6Manual No. 016-0171-148 81Basic OperationField BoundariesA field boundary and spray zone map can be created for each job on the Envizio Pro or Envizi
Chapter 682 Envizio Pro and Envizio Pro II Installation and Operation ManualField Boundary ToolsThe following Menu tools and features are available wh
6Manual No. 016-0171-148 83Basic OperationPause, Resume and End BoundariesThe following icons will appear on the Guidance screen while a field boundar
Chapter 684 Envizio Pro and Envizio Pro II Installation and Operation ManualPrescription Maps and Variable RatesWith the optional VRA feature enabled,
6Manual No. 016-0171-148 85Basic OperationApplying Rx MapsA prescription map may be applied to either product during the Start Job sequence. With the
Chapter 686 Envizio Pro and Envizio Pro II Installation and Operation Manual2. A list of available prescription maps is displayed on the Start Job - S
6Manual No. 016-0171-148 87Basic OperationSystem AlarmsImportant warning and alert information is immediately displayed on the screen in the Alarms ar
Chapter 688 Envizio Pro and Envizio Pro II Installation and Operation ManualHiding the Alarms AreaOnce the operator has reviewed any alert information
CHAPTER7Manual No. 016-0171-148 89C hapter 7Tools MenuAccessing and Navigating the Tools MenuAfter the initial setup wizards are complete, all setting
Comments to this Manuals